7.4 V 2600mAh Cylindrical Lithium ion battery Packs With Protection IC
Product Details:
| Place of Origin: | China |
| Certification: | CE UL ISO KS |
| Model Number: | -18650 2600 mAh |
|
Detail Information |
|||
| Name: | Cylindrical Lithium Ion Battery | Li-Ion Size:: | 2 X 18650 (cylindrical) |
|---|---|---|---|
| Capacity:: | 2600 MAh | Working Voltage:: | 7.4V |
| Diameter*Height: | 18*65mm | Iedance: | <190 MΩ |
| Standard Charge Current: | 0.5C (1300mA) | Standard Discharge Current:: | 0.2C (520mA) |
| Cycle Life: | 500 - 1000 Cycles | ||
| Highlight: | 7.4V Li Ion Battery Pack,2600mAh Lithium Ion Battery Packs,Cylindrical Lithium ion battery |
||
Product Description
7.4 Volt 2600 mAh Li-Ion Battery Pack - With Protection IC
Features
- High Energy Density: The 18650 format offers a high capacity of 2600mAh in a compact size, providing long runtime for portable devices .
-
Integrated Comprehensive Protection: The built-in Protection IC safeguards the battery and the host device against common fault conditions like overcharge, over-discharge, overcurrent, and short circuits, enhancing safety and reliability .
-
Long Cycle Life: Can withstand over 500 charge-discharge cycles while maintaining more than 80% of its initial capacity, ensuring good longevity .
-
Wide Operating Temperature Range: Suitable for use in various environments .
-
Low Self-Discharge: Retains charge for extended periods when not in use .
Specifications
|
Diameter*Height |
18*65mm |
|
Nominal Voltage |
7.4V |
|
Nominal Capacity |
2600mAh |
|
Iedance |
≤190mΩ |
|
Discharge cut-off voltage |
5.5V to 6.0V (2.5V to 3.0V per cell) |
|
Charge voltage |
8.4V (4.2V per cell) |
|
Standard charge |
0.5C (1300mA) to 8.4V
|
|
Standard discharge current |
0.2C (520mA)
|
|
Working teerature |
Charge:0-45 degree |
|
Discharge:-20-60 degree |
|
|
Storage teerature |
minus 20 - 55degree |
|
Self-Discharge Rate |
<3% per month |
|
Cycle life |
500 - 1000 cycles |
![]()
Protection Features (Integrated Protection IC)
The battery pack includes a Protection Circuit Module (PCM) with the following typical protection parameters :
- Overcharge Protection: 4.25V ± 0.025V per cell / 4.28V ± 0.02V per cell (-ΔV detection, cuts off charge circuit)
-
Overcharge Release: 3.8V ~ 4.2V per cell (Automatic recovery when voltage drops)
-
Over-Discharge Protection: 2.4V ± 0.05V per cell / 2.50V ± 0.10V per cell (-ΔV detection, cuts off discharge circuit)
-
Over-Discharge Release: 2.8V ~ 3.2V per cell (Automatic recovery after charging)
-
Overcurrent Protection: 3A ~ 6A / 10A ~ 17A (-ΔV detection, cuts off discharge circuit)
-
Short Circuit Protection: Immediate trip (e.g., VSS < 0.15V for t > 10ms)
-
Temperature Protection: NTC thermistor typically integrated for external monitoring or internal cutoff
-
Balance Function: Passive cell balancing during charging to ensure voltage uniformity between cells
Applications
- Consumer Electronics: Cordless phones, portable audio players (MP3), digital cameras, camcorders, handheld gaming devices .
- Portable Lighting: High-lumen flashlights, LED work lights, emergency lights .
- Communication Devices: Two-way radios, intercoms .
- Medical Equipment: Portable monitors, diagnostic devices .
- Industrial Instruments: Handheld scanners, data loggers, measurement devices .
- Other: Toys, laser pointers, small fans, portable printers .
Warnings & Precautions
Charging
- Use a Li-ion Specific Charger: Always use a charger designed for Li-ion chemistry and configured for this battery's voltage (8.4V) and current limits (≤2000mA).
-
Avoid Overcharging: The protection IC is a backup. Do not rely on it exclusively. Do not leave the battery charging unattended for extended periods. Disconnect the charger once charging is complete .
-
Temperature Monitoring: Charge only within the specified temperature range (0°C to +45°C). Charging outside this range, especially below 0°C, can cause permanent damage .
Discharging
- Avoid Deep Discharge: While the protection IC will cut off discharge, avoid regularly draining the battery until the device shuts off. Do not discharge below the cut-off voltage .
-
Current Limits: Do not exceed the maximum continuous discharge current (2000mA or 2600mA as per spec). Exceeding limits causes overheating, damage, and safety risks .
-
Temperature Management: Avoid discharging outside the recommended range (-20°C to +60°C). Extreme cold reduces performance; extreme heat accelerates aging and increases risks .
Storage
- Partial Charge Storage: For long-term storage (longer than one month), store the battery at a 30%-50% State of Charge (SOC). Avoid storing fully charged or fully discharged .
-
Cool and Dry Environment: Store in a cool, dry place away from direct sunlight and heat sources. Ideal storage temperature is -5°C to +20°C .
-
Regular Checks: If stored for very long periods, check the voltage every 3-6 months and recharge if it drops near the over-discharge protection voltage.